to the LAN Host Mode FAQ. If the site requires that the Px have a static IP
address, refer to the Static IP Address FAQ.
-How do I configure the Allworx Px 6/2 Expander for LAN Host
Mode?
If the Allworx server is in LAN Host mode and it is NOT the site's DHCP
server, Px network configuration changes may have to be made. However,
if the site's DHCP server supports Option #66, the changes are limited to
the DHCP server side. If it supports Option #66, enter the Allworx server's
IP address as the TFTP server address in the DHCP server's database.
If the site's DHCP server does not support Option #66, settings must be
changed on the Px. Perform the following steps:
First, put the Px in Configuration Mode:
Remove the power and Ethernet cables from the Px unit.
Plug the power back into the Px unit. Make sure the Ethernet is not
connected. Wait for the Power and Port LEDs to go solid amber
(about 45 seconds). This indicates that it is in Configuration Mode.
Then, access the Px's admin page from the service PC:
Connect the service PC directly to the unit using an Ethernet cable.
DHCP is enabled on the Px unit while in Configuration Mode.
Open a command window on the service PC by clicking Start, Run, then
typing cmd into the Open field and then clicking OK.
On the command line in the window, type: ipconfig /release and press
the Enter key.
Once the command prompt is re-displayed, type: ipconfig /renew and
press the Enter key.
Once the command prompt is re-displayed, enter the Px's IP address
(192.168.2.254) into the address field of the PC's web browser and
click Go.
Change the Px's network settings:
Into the Boot Server IP Address field, enter the Allworx server's LAN IP
address.
If the Px Password has not been set, set it by entering a password into
the New Password and Confirm Password fields. We recommend
using the Px's MAC address or use the same password as the
Allworx server. In any case, save a copy of the password.
Click Update.
Click Restart. Click OK on the confirmation boxes.
To get into Normal Mode, wait until the Restart sequence starts (Power